1. Product Description

The Meanwell LRS-600 PSU Enclosure Mount is a model-specific terminal safety cover designed exclusively for the Meanwell LRS-600 power supply series. Its dual-chamber layout physically separates mains AC input wiring from low-voltage DC output connections, while the complete terminal shroud encloses exposed connections and provides clean cable exit paths for CNC, 3D-printing, LED, workshop, and control-panel installations.

2. Key Features & Included Components

  • Dual-Chamber Isolation: An internal dividing barrier separates mains AC wiring from low-voltage DC output connections.
  • Complete Terminal Shroud: Encloses the open terminal area to reduce accidental contact and provide a clean finished installation.
  • Reinforced Construction: Printed in rigid PETG-CF for dimensional stability, durability, and heat resistance beside an operating power supply.
  • Included Components: 1 × PETG-CF enclosure mount, 1 × MnN Proto-Lab press-fit IEC C14 socket, voltage-appropriate output hardware, and mounting screws.
  • Power Supply Not Included: The Meanwell LRS-600 power supply is purchased separately.

3. Material & Component Specifications

Enclosure Body

  • Material: PETG-CF, carbon-fibre reinforced PETG.
  • Finish: Satin black.
  • Characteristics: High rigidity, dimensional stability, impact resistance, chemical resistance, and suitable thermal performance for the intended enclosure application.

Electrical Connection Components

  • AC Input: MnN Proto-Lab press-fit IEC C14 panel-mount socket.
  • IEC Conductors: Solid copper with tin plating.
  • 5 V, 12 V & 15 V Output: M8 high-current 100 A binding posts.
  • 24 V, 27 V, 36 V & 48 V Output: Gold-plated binding posts.

4. Compatibility

Parameter Specification Notes
Compatible PSU Meanwell LRS-600 series only Not compatible with LRS-350 or unrelated power-supply models.
Mounting Method Model-specific bolt-on fit Fits over the LRS-600 terminal area using applicable existing chassis mounting points.
Mounting Fasteners Included Use only the supplied or correctly specified replacement fasteners.

Note: Slight dimensional variation may occur between manufacturing batches due to the additive manufacturing process.

5. Voltage Variant & SKU Matrix

Output Voltage Output Hardware SKU
5 V M8 high-current 100 A binding posts LRS600-BLK-05
12 V M8 high-current 100 A binding posts LRS600-BLK-12
15 V M8 high-current 100 A binding posts LRS600-BLK-15
24 V Gold-plated binding posts LRS600-BLK-24
27 V Gold-plated binding posts LRS600-BLK-27
36 V Gold-plated binding posts LRS600-BLK-36
48 V Gold-plated binding posts LRS600-BLK-48

6. Performance & Environmental Considerations

  • Thermal Performance: PETG-CF provides suitable heat resistance for the intended location beside an operating LRS-600 power supply.
  • Chemical Resistance: Resistant to common workshop oils and mild cleaning agents. Confirm compatibility before exposure to aggressive chemicals.
  • Physical Protection: The enclosure helps reduce accidental finger or tool contact with the terminal area when correctly assembled.

7. Installation Responsibility & Safety

  • Mains Wiring: Installation involves terminating mains-voltage wiring between the included IEC socket and the power supply terminals.
  • Installer Responsibility: The installer is responsible for using appropriate wire ratings, insulation, protective earthing, strain relief, termination methods, and applicable electrical protection.
  • Compliance: All assembly and use must comply with the electrical safety requirements and regulations applicable to the installation location.
  • Pre-Use Inspection: Check polarity, earth continuity, insulation, terminal tightness, cable security, and enclosure fit before applying power.
  • Damage: Do not energise the assembly if any enclosure part, conductor, terminal, insulation, or connection is damaged or insecure.

8. Revision Summary

REV2: Added the complete seven-variant SKU and output-hardware matrix, clarified included components, and updated installation responsibility and safety wording.